SVL is a certified R&D centre by The Department of Scientific & Industrial Research (DSIR). SVL is home to state of the art testing facilities, manned by a highly motivated and competent R & D team.

SVL is constantly updating and improving its testing facilities to meet harsher testing standards required by its customers. The latest additions to the wide range of testing equipment include
  • Noise, Vibration & Harshness Tester (NVH)
  • High Function Durability Bench x 4
  • Slugging Bench
The testing facilities are available to external organisations for hire. To find out more about the facilities, email us at
 
 
Test Conducted
  • Cooling Capacity of Air-Conditioning System
  • Heating capacity of Heater Unit Assembly
 
Features
  • Temp: 15 ~ 50 °C
  • % RH: 40 ~ 80
  • Cooling capacity: 800 ~ 10000 Kcal/hr
  • Evaporator Air Flow: 2.5 ~ 10 m/sec
  • Capacity: 30 KW
  • Temp: 35 ~ 100 °C
  • Flow Rate: 0 ~ 1500 l/hr at 3 kg/cm2
  • Capacity: 1000 ~ 1500 Kcal/r
  • Temp: Ambient ~ 60 °C
  • Comp Revolution: 600 ~ 3000 rpm
  • Temp: Up to 120 °C
 
 
 
 
Test Conducted
  • Efficiency test of automotive air-conditioners
    (ODCD + Cool Down Test)
  • Efficiency test of automotive engines
  • Automotive environment simulation
 
Features
  • Temp Range: 10 °C above ambient ~ 60 °C
  • Humidity: 60% at 45 °C & 80% at 35 °C
  • Car Velocity Range: Up to 120 Kmph
  • Solar Radiation condition: Up to 1200 watts/m2
  • Driving Type: Front wheel & Rear wheel drive both (2 WD)
  • Inner Dimensions of Environmental Chamber: 16m x 7m x 7m
  • Blower Air Volume: 250,000 m3/hr
 
 
 
 
 
Test Conducted
  • Resonance search
  • Vibration durability test
 
Features
  • Operating Frequency: 5 ~ 2000 Hz
  • Max. Displacement: 40 mm (p-p)
  • Pay Load Capacity (on ILS): 200 kg
  • Vibration controls: Sine, Random, Shock
 
 
 
 
Test Conducted
  • Temperature Cycle Test
  • High Temperature Holding Test
  • Low Temperature Holding Test
  • Temperature with Humidity Cycle
 
Features
  • Inner Dimension : 1m x 1m x 1m
  • Temperature Range: -40 ~ 200 °C
  • Temperature Accuracy: ±1 °C
  • Relative Humidity: 20 ~ 97 %
  • Temperature Change Rate: 1 °C/min (Empty Chamber)
 
 
 
 
Test Conducted
  • Low Temperature Holding Test
  • Thermal Shock Test
 
Features
  • Inner Dimension: 1m x 1m x 1m
  • Temperature Range: -40 °C to Ambient
  • Temperature Accuracy: ±1 °C
 
 
 
 
Test Conducted
  • High Temperature Holding Test
  • Thermal Shock Test
 
Features
  • Inner Dimension: 1m x 1m x 1m
  • Temperature Range: Ambient to 200 °C
  • Temperature Accuracy: ±1 °C
 
 
 
 
Test Conducted
  • High Temperature Holding Test
  • Thermal Shock Test
 
Features
  • Inner Dimension: 1m x 1m x 1m
  • Temperature Range: Ambient to 400 °C
  • Temperature Accuracy: ±1 °C
 
 
 
 
Test Conducted
  • Anti-corrosive test as per JIS Z2371
 
Features
  • Inner Dimension: 1m x 0.75m x 0.75m
  • Temperature Range: Ambient ~ 50 °C
  • Temperature Accuracy: ±1 °C
  • Humidity: Up to 97% RH
  • Fog collection: 0.5 ~ 2.0 mm/hr
 
 
 
 
Test Conducted
  • Anti-corrosive test as per JIS H8681
 
Features
  • Inner Dimension: 1.2m x 0.75m x 0.9m
  • Temperature Range: Ambient ~ 50 °C
  • Temperature Accuracy: ±1 °C
  • Humidity: Up to 97% RH
  • Fog collection: 0.5 to 2.0 mm/hr
 
 
 
 
Test Conducted
  • Tear Down Test
  • Compressor Durability Test
 
Features
  • Suction Pressure: 0.5 ± 0.2 to 3.7 ± 0.5 kg/cm2
  • Discharge Pressure: 12 ± 0.5 to 29 ± 1.5 kg/cm2
  • Compressor Rotation: 900 ~ 7000 rpm